home Bangkokcable.com
Print this page
section | main menu

1.8/3(3.6) kV CV (CE optional)*
IEC 60502-1 (3 CORE)
CV(3 CORE) 1.8/(3.6)kV CABLE

Construction
1. Conductor : Compact round stranded annealed copper wires
2. Insulation : Cross-linked polyethylene (XLPE)
3. Filler : Polypropylene (Non-hygroscopic material)
4. Binding tape : Polyester / Spunbond tape
5. Metallic screen : Copper tape
6. Binding tape : Polyester / Spunbond tape
7. Sheath : Polyvinyl chloride (PVC), ( Optional : PE )*
Application
For general purpose power distribution in dry and wet location, installation in exposed,
in conduit or duct or direct burying in ground.

Conductor
Thickness
of
Insulation
(Nominal)


mm
Thickness
of
Sheath
(Nominal)


mm
Overall
diameter
(Approx.)



mm
Maximum
DC.
Conductor
resistance
at 20°C

ohm/km
Current
rating
in air



A
Cable
weigth
(Approx.)



kg/km
Standard
packing
length



m
Size



mm2
Number
of wires
(Min.)



Diameter
(Approx.)



mm
10 6 3.72 2.0 1.8 24 1.83 67 650 500
16 6 4.69 2.0 1.8 26 1.15 90 870 500
25 6 5.90 2.0 1.8 29 0.727 120 1200 500
35 6 6.95 2.0 1.8 31 0.524 145 1530 500
50 6 8.33 2.0 1.9 35 0.387 175 1980 500
70 12 9.73 2.0 2.0 38 0.268 220 2660 500
95 15 11.43 2.0 2.2 42 0.193 275 3550 500
120 18 12.95 2.0 2.3 46 0.153 320 4380 500
150 18 14.27 2.0 2.4 49 0.124 365 5300 300
185 30 15.98 2.0 2.5 53 0.0991 415 3500 300
240 34 18.47 2.0 2.7 59 0.0754 495 8400 250
300 34 20.68 2.0 2.8 64 0.0601 570 10300 200
400 53 23.39 2.0 3.1 71 0.0470 655 13000 150
 

Copyright 2005 . www.bangkokcable.com